ElectraClean: A
gentle yet effective cleaner specifically formulated to
clean any type of ESD flooring, esd epoxy or floor
paint. Regular cleaners and detergent compounds leave
harmful insulative residues reducing the static-control
properties of your highly specialized flooring, Not SO with
ElectraClean! ElectraClean works great in both power scrub
AND mop on applications, removing dirt and soil while
maintaining or increasing the conductivity of your critical
esd flooring substrate. Super Concentrated!!! Why pay for
water (unless it's Fiji ;)
ELECTRACLEAN
MAIN PAGE
MORE ESD FLOOR CARE
PRODUCTS
PN: E-Clean, ESD Floor Cleaning Solution
Material Safety Data Sheet
_______________________________________________________________________________
SECTION I - IDENTITY
_______________________________________________________________________________
PN: E-Clean, Static Dissipative ESD Floor Cleaning Solution
United Static Control Products Incorporated
POB 19252, 4878 Lakeview Cir
Hazardous - NO
Health: 1
Flammability: 0
Reactivity: 0
Personal Protection: B
Telephone Number for Information ------------------------------------
(719) 676-3928 4 = Most Hazardous
Date Prepared Emergency Phone Number
06/16/09 1 719 676 3928 or Poison Center
Prepared By Andrew Vadasz
_______________________________________________________________________________
SECTION II - HAZARDOUS INGREDIENTS
_______________________________________________________________________________
Hazardous Components PEL TWA STEL Other Limits %
CAS Reg# (opt)
*DIETH. GLYCOL METH. ETHER N.A. N.A. N.A. < 15
# 111-77-3
*LISTED CHEMICAL SUBJECT TO REPORTING REQUIREMENT OF SCT.313 OF TITLE III.
_______________________________________________________________________________
SECTION III - PHYSICAL/CHEMICAL CHARACTERISTICS
_______________________________________________________________________________
Boiling point - 215F Specific Gravity (Water=1) - 1.0
Vapor Pressure (mm Hg) - 18.0 Melting Point - N.A.
Vapor Density (air=1) - 1.06 Evaporation Rate (Butyl Acetate=1) -0.28
Viscosity (CPS) - NA Decomposition Temperature -NA.
Auto Ignition Temp. - NA Solubility in Water -COMPLETE
pH - 7.0 +/-.5
Appearance and Odor -LIGHT GREEN COLORED LIQUID, PLEASANT ODOR
_______________________________________________________________________________
SECTION IV - FIRE AND EXPLOSION HAZARD DATA
_______________________________________________________________________________
Flash Point - N.A. Flammable Limits
LEL - N.A. UEL - N.A.
Extinguishing media - WATER SPRAY
Fire Fighting Procedure - COOL CONTAINERS WITH WATER
Fire and Explosion Hazards - NONE
_______________________________________________________________________________
SECTION V - REACTIVITY DATA
_______________________________________________________________________________
Stability - STABLE
Conditions to Avoid - N.A.
Incompatibility - STRONG OXIDIZERS
Hazardous Decomposition or Byproduct - THERMAL DECOMPOSITION MAY YIELD
CARBON MONOXYDE
Hazardous Polymerization - WILL NOT OCCUR
Conditions to Avoid - N.A.
_______________________________________________________________________________
The information herein is based on data considered accurate. However, no
warranty is expressed or implied regarding the accuracy of these data or
results to be obtained from use thereof.
Essentially similar to OSHA form # 174
_______________________________________________________________________________
SECTION VI - HEALTH HAZARD DATA
_______________________________________________________________________________
Routes of entry:
Inhalation - NO Skin - NO Ingestion - YES
Health Hazards-Acute: CAUSES EYE AND SKIN IRRITATION
CHRONIC: REDNESS OF SKIN
Carcinogenicity: NO
NTP - N.A. IARC Monographs - N.A. OSHA Regulated - NO
Signs and Symptoms of Exposure - IRRITATION, REDNESS OF SKIN, EYES
Medical Conditions Aggravated - DERMATITIS
Emergency and First Aid Procedures - WASH CONTACT AREAS WITH PLENTY OF WATER:
15 MINUTES. INGESTION: DO NOT INDUCE VOMITING
CALL PHYSICIAN IMMEDIATELY
_______________________________________________________________________________
SECTION VII - PRECAUTIONS FOR SAFE HANDLING AND USE
_______________________________________________________________________________
Steps to be Taken in Case Material is Released or Spilled - DIKE AND
COLLECT MATERIAL INTO PLASTIC CONTAINER. WATER RINSE AND DRAIN, FLUSH
SMALL AMOUNTS. (BIODEGRADABLE)
Waste Disposal Method - USE SANITARY LANDFILL DISPOSAL. (NOT A HAZARDOUS
WASTE) FOLLOW STATE AND LOCAL REGULATIONS (RCRA; SUBTITLE D)
Precautions to be Taken in Handling and Storage -
DO NOT MIX WITH OTHER CHEMICALS.
AVOID PROLONGED CONTACT. KEEP FROM FREEZING.
Other Precautions - STORE IN SECURE AREA. AVOID FOOD OR FEED CONTAMINATION.
KEEP OUT OF REACH OF CHILDREN !
_______________________________________________________________________________
SECTION VIII - CONTROL MEASURES
_______________________________________________________________________________
Respiratory Protection - NOT REQUIRED WITH NORMAL USE
IN WELL VENTILATED AREA
Ventilation Local Exhaust - N.A.
Mechanical - N.A.
Special - N.A.
Other - ASSURE FRESH AIR CIRCULATION.
Protective Gloves - REQUIRED: RUBBER, PLASTIC
Eye Protection - RECOMMENDED: SAFETY GLASSES
Other Protection - NA.
Work/Hygienic Practices - DO NOT EAT, DRINK NEXT TO MATERIAL.
WASH HANDS/FACE AFTER WORK.
_______________________________________________________________________________
SECTION IX - TRANSPORTATION 49 CFR
_______________________________________________________________________________
Unit Cont. - 55,30,5,1 GAL. PLASTIC CONT Report Qty. (Lbs) - NA.
OSHA - NOT REGULATED Labels - NONE
DOT - NOT REGULATED
UN - NOT REGULATED
_______________________________________________________________________________
Vendor assumes no responsibility for injury to vendee or third person proxim-
ately caused if reasonable safety procedures are not adhered to as stipulated
in the data sheet. Additionally, vendor assumes no responsibility for injury to vendee or third persons
proximately caused by abnormal use of the material
even if reasonable safety procedures are followed. Further more, vendee
assumes the risk in use of the material.